PowerPDU 8QS
NETIO PowerPDU 8QS is a PDU (Power Distribution Unit) with eight power outputs (8x IEC-320 C13) controlled and metered over a LAN. It fits into a 19” cabinet (1U). Each output can be switched on/off individually. PowerPDU 8QS supports two channels for electrical measurements: the PDU as a whole (all outputs combined), and the first output separately (All Outputs + 1). A digital input (DI) can be used to control the outputs or count S0 pulses (electricity meter output).
NETIO PowerPDU 8QS can be configured with a web browser (allows output control, connection to NETIO Cloud, Open API communication settings, etc.).
Thanks to the Open API, integration with third-party systems using various protocols (JSON, Modbus/TCP, SNMP, MQTT-flex, Telnet, ...) is easy. Ready-made AV drivers make it simple to connect the NETIO PDU to professional Audio/Video systems such as Neets, Crestron, Control4, RTI, Savant and more.
With the NETIO Cloud service, the outputs can be controlled from anywhere. The NETIO Cloud service, provided for a fee, uses SSL security and servers in Europe.
The NETIO Mobile2 app controls each output individually over LAN (local network).
To switch the outputs on in a sequence, a power-up delay can be configured for each output.
TYPICAL APPLICATIONS
PRODUCT COMPARISON
Connection | Switched Outputs | Metered Channels | Smart Switching | Inputs | NFC | Web Interface | NETIO Cloud | Lua scripts | WatchDog function | Scheduler function | Mobile App | HTTPs | Open API | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PowerPDU 4C | 2xLAN | 4xC13 | 4 | ZCS | RS-232 | - | YES | YES | YES | YES | YES | iOS + Android | YES | 15 protocols |
PowerPDU 4PS | LAN | 4xC13 | - | ZVS | - | - | YES | YES | - | - | YES | Android | - | 10 protocols |
PowerPDU 8QS | LAN | 8xC13 | 1+1 | ZVS | 1xDI | - | YES | YES | - | - | YES | Android | - | 10 protocols |
PowerPDU 4PZ | LAN WiFİ | 2+2 | 2 | ZCS / - | 2xDI (S0) | YES | YES | YES | - | - | YES | Android | - | 10 protocols |
PowerPDU 3Px | LAN | 3x | - | ZVS | - | - | YES | YES | - | - | YES | Android | - | 10 protocols |
PowerPDU 4Kx | LAN | 4x | 4 | ZCS | - | - | YES | YES | - | - | YES | Android | - | 10 protocols |
PowerCableRES T101x |
WiFi | 1x | 1 | ZCS | - | YES | YES | YES | - | - | YES | Android | - | 10 protocols |
TECHNICAL SPECIFICATIONS
OPEN API: SUPPORTED M2M PROTOCOLS
One Open API protocol can be used at a time, chosen from among the supported M2M protocols:
SNMP v1 | AN11 | AN41 | |
---|---|---|---|
SNMP v3 | |||
MQTT-flex | AN40 | ||
Telnet | AN10 | ||
Modbus/TCP | AN27 | AN22 | AN37 |
JSON over HTTP | AN21 | AN30 | AN42 |
XML over HTTP | AN20 | AN31 | |
URL API (http get) | AN19 | AN29 | |
HTTP(s) Push JSON | |||
HTTP(s) Push XML |
Regardless of the Open API used, the PowerPDU 8QS can be always controlled from its web interface and from the NETIO Cloud service. The customer can take advantage of the NETIO Cloud service and one Open API protocol simultaneously
Useful links
ELECTRICAL MEASUREMENTS
NETIO PowerPDU 8QS measures electrical parameters – at the input for the device as a whole (All Outputs) as well as at the first output (Output 1). Measured values are displayed in the web administration interface and at the same time are accessible via Open API protocols. NETIO PowerPDU 8QS measures with accuracy better than 1%.
Parameters measured for the whole device:
Parameters measured for output 1:
DI (DIGITAL INPUT)
A digital input (DI) can be used to control the outputs or count S0 pulses.The DI can be connected to a button (dry contact) or used as a S0 pulse counter for reading energy consumption from an external electricity meter.
The DI state and the S0 counter value are shown in the web interface and accessible over Open API.
NETIO CLOUD
The product can be connected to NETIO Cloud. Control 100 outputs from a single web screen!NETIO Cloud is an ideal solution for remote control and restarting. It is accessible via any web browser: https://cloud.netio-products.com/
The NETIO Cloud service is provided for a fee and supports NETIO products.
INDUSTRIAL PRODUCT QUALITY
NETIO PDUs are made with quality in mind. Each unit includes a set of supporting functions to ensure reliability and long service life of the product in real-life conditions.
ZVS (ZERO VOLTAGE SWITCHING)
An important feature of the NETIO PowerPDU 8QS is ZVS (Zero Voltage Switching). ZVS controls the exact time when the mechanical relay contacts close and open. The relay contacts switch the output on or off when the voltage crosses the zero level.
SCHEDULER (TIMED SWITCHING OF INDIVIDUAL OUTLETS)
With the Scheduler (timer) function, each output can be individually switched on or off at specified times and days of week. The switching times are easily configured in a graphical interface.
POWER-UP STATE
For some applications, it is important to set the power output state immediately after the device is powered on (or the power is restored after a failure). With some machines it is important to avoid momentary switch-on or switch-off. This parameter therefore defines the behavior of the power output before the standard communication with a master system starts to work.
Delay sequence when switching outputs on (PowerUp delay)
After a power outage, some electrical equipment can be switched on with a delay to avoid overloading and tripping circuit breakers. With the PowerPDU 8QS, use these parameters: “Power-Up state” = ON / LAST, and “Output PowerUp interval” = power-up delay before switching that particular output on.
Glossary: PowerUp stateMOBILE APPLICATION
PowerPDU 8QS can be controlled over the local network using the NETIO Mobile 2 app (for Android mobile devices).
For the moment, NETIO Mobile 2 is not available for iOS users. We recommend using third-party apps:
GENERAL PROPERTIES
Switched Power Outputs |
Metered channels |
LAN | Web | NETIO Cloud | Lua scripts | Watchdog | Scheduler | Mobile App | Open API |
19“ 1U montage |
Switching | |
PowerPDU 4C | 4xC13 | 4 | 2 | Yes | Yes | Yes | Yes | Yes | iOS + Android | 15 protocols |
RM1 / RM2 required |
ZCS |
PowerPDU 4PS | 4xC13 | - | 1 | Yes | Yes | - | - | Yes | Android | 10 protocols |
RM1 / RM2 ​required |
ZVS |
PowerPDU 8QS | 8xC13 | 2 | 1 | Yes | Yes | - | - | Yes | Android | 10 protocols | Yes | ZVS |
FAQ
To reset the product to factory defaults, use the “RESET” button. When plugging in the device, hold the “RESET” button for about 10 seconds, until the yellow LED on the RJ45 jack flashes 3 times. Factory settings will be restored (Load do defaults).
For the current procedure, see the supplied QIG (Quick Installation Guide) for the product.
It is available for download at this page as well as included in the product package.
Yes. When the PowerPDU is powered up, all outputs are set according to the configured PowerUp state (On / Off / LAST value). The parameter can be set in the web interface in the detailed configuration for each output.
For Android mobile devices, please upgrade to NETIO Mobile 2. We are working on a mobile app for iOS devices.
Remote restart is useful e.g. to control the power to a router, where a simple “power off” action would make it impossible to send the subsequent “power on” action. With the Restart – “Short OFF” action (can be invoked from the web interface), it is possible to switch off the power e.g. for 5 seconds, and then the PowerPDU switches it back on automatically, without further user intervention.
Yes, NETIO PowerPDU 8QS supports the Scheduler function.
Yes. All NETIO products support the Open API. We are continuously publishing ANxx (Application Notes) that describe how to connect the product to various third-party systems. NETIO PowerPDU 8QS can also be controlled using NETIO Cloud.
Yes, level 3 protection is included.
Yes. However, there is one button that controls all outputs. Press the “TGL” button 3x rapidly:
- If any outputs are On (1), they are switched Off (0)
- If all outputs are Off (0), all outputs are switched On (1)
DOWNLOAD